EÜAŞ HEADQUARTERS BUILDING SEISMIC PERFORMANCE ASSESSMENT AND RETROFIT Project Description:EÜAŞ Headquarters Building Seismic AssessmentLocation:Ankara / TurkeyClient:Optimal – EÜAŞYear:2018Project Details:Seismic Assessment works of 14 story EÜAŞ Headquartes Building in Ankara. Nonlinear Time History Analysis have been peformed to find the performance of the building for a probable earthquake in the region. Our References